Basemark Web 3.0

Web Browser Performance Testing Tool

Cross-Platform Benchmarking Tool

Basemark Web 3.0 is a comprehensive web browser performance benchmark that tests how well your mobile or desktop system can use web based applications. This benchmark includes various system and graphic tests that use the web recommendations and features. After running the benchmark you will see how your system performed compared to other systems and browsers in Basemark Powerboard. Basemark Web 3.0 measures real-world client-side performance to detect browser bottlenecks.

START

Versatile

Basemark Web 3.0 is a hardware- and platform-independent, supporting virtually all modern browsers, operating systems, and mobile or desktop systems.

Web 3.0 Features

  • Low-level JavaScript calculations (ECMAScript), designed to test the core of JavaScript
  • Graphically intense content, e.g. WebGL 2.0, that uses mainly GPU of the device
  • Tests built with popular JavaScript frameworks (e.g. jQuery, Angular, and Backbone), and Document Object Model (DOM), as well as popular CSS features
  • Basemark Web 3.0 will also contain a Conformance Suite, which doesn’t contribute to overall score, but tests the browser’s conformance.

Basemark has a long history in creating industry-leading benchmarks for mobile devices, virtual reality systems and browsers. Basemark Web 3.0 is a major milestone in developing trustworthy benchmarks for modern browsers, including WebGL.

Neil TrevettPresident of the Khronos Group

Corporate version

We offer a special version of Basemark Web 3.0 to corporate customers. They can select if they want to submit results to Power Board database and have more instruments to adjust other benchmarking parameters.

Feel free to contact us if you’re interested in purchasing corporate license and we’ll tell you more.

CONTACT US

Community Mode

The Community Mode can be activated easily via specific URL, and after this Basemark Web 3.0 can be controlled only via URL calls. All results and details are written to the browser console in machine-readable mode, so this version is the most suitable for automated bots. All tests are run on screen the same way as in Free and Corporate Version.

https://web.basemark.com/?mode=community activates the the Community Mode and turns the UI to a simplified version. This URL also activates console logging which contains details about the current benchmark configuration, system and information for changing different configurations

https://web.basemark.com/?mode=free exits the Community Mode, activates the normal UI, and deactivates the console.

Terms of Use

Basemark® Web 3.0 is available in “Community Mode” for open-source projects. The Community Version can be used solely in non-commercial use to detect open-source project defects. Using the Community Version for any other purposes is strictly forbidden. Commercial use always requires a Corporate Version.

Conformance tests

Basemark Web 3.0 also contain a Conformance Suite, which doesn’t contribute to the overall score. It tests the browser’s conformance.

https://web.basemark.com/?conformance=1
turns Conformance Tests ON

https://web.basemark.com/?conformance=0
turns Conformance Tests OFF (default)

Suite selection

https://web.basemark.com/?suite=0
Selects All suites (default)

https://web.basemark.com/?suite=1
Selects Core Suite only

https://web.basemark.com/?suite=2
Selects Graphics Suite only

https://web.basemark.com/?suite=3
Selects Generic Suite only

Battery tests

https://web.basemark.com/?battery=1
turns battery test ON

Basemark Web 3.0 will loop all tests until device battery is exhausted or user/operating system terminates the browser. When the battery test mode is turned on, the console will have inside current configuration line

Battery: ON, Results URL: http://web.basemark.com/result/?<UID_generated_by_Basemark_Web_3.0>

NOTE: This URL needs to be saved, because that is only way to access Battery run results after battery is exhausted!

https://web.basemark.com/?battery=0
turns the battery test OFF (default)

Running the test

https://web.basemark.com/run/ – starts testing.

Parameters “battery”, “conformance”, and “suite” can be combined in one URL call using “&” as a separator.

For example, resetting Basemark Web 3.0 to defaults can be done via URL:

https://web.basemark.com/?battery=0&conformance=0&suite=0

Community Mode

The Community Mode can be activated easily via specific URL, and after this Basemark Web 3.0 can be controlled only via URL calls. All results and details are written to the browser console in machine-readable mode, so this version is the most suitable for automated bots. All tests are run on screen the same way as in Free and Corporate Version.

ACTIVATE

https://web.basemark.com/?mode=community activates the the Community Mode and turns the UI to a simplified version. This URL also activates console logging which contains details about the current benchmark configuration, system and information for changing different configurations

DEACTIVATE

https://web.basemark.com/?mode=free exits the Community Mode, activates the normal UI, and deactivates the console.

Terms of Use

Basemark® Web 3.0 is available in “Community Mode” for open-source projects. The Community Version can be used solely in non-commercial use to detect open-source project defects. Using the Community Version for any other purposes is strictly forbidden. Commercial use always requires a Corporate Version.

Conformance tests

Basemark Web 3.0 also contain a Conformance Suite, which doesn’t contribute to the overall score. It tests the browser’s conformance.

https://web.basemark.com/?conformance=1
turns Conformance Tests ON

https://web.basemark.com/?conformance=0
turns Conformance Tests OFF (default)

Suite selection

https://web.basemark.com/?suite=0
Selects All suites (default)

https://web.basemark.com/?suite=1
Selects Core Suite only

https://web.basemark.com/?suite=2
Selects Graphics Suite only

https://web.basemark.com/?suite=3
Selects Generic Suite only

Battery tests

https://web.basemark.com/?battery=1
turns battery test ON

Basemark Web 3.0 will loop all tests until device battery is exhausted or user/operating system terminates the browser. When the battery test mode is turned on, the console will have inside current configuration line

Battery: ON, Results URL: http://web.basemark.com/result/?<UID_generated_by_Basemark_Web_3.0>

NOTE: This URL needs to be saved, because that is only way to access Battery run results after battery is exhausted!

https://web.basemark.com/?battery=0
turns the battery test OFF (default)

Running the test

https://web.basemark.com/run/ – starts testing.

Parameters “battery”, “conformance”, and “suite” can be combined in one URL call using “&” as a separator.

For example, resetting Basemark Web 3.0 to defaults can be done via URL:

https://web.basemark.com/?battery=0&conformance=0&suite=0

Versions Comparison

Feature Free Community Corporate
Overall score Yes Console Yes
Detection details Yes Console Yes
Problems indication Yes Console Yes
Suite scores No Console Yes
Individual test scores No No Yes
Test meta information No No Yes
Select suite No URL Yes
Select test No No Yes
Conformance testing Opt-out Opt-in Opt-in1
Automated result submit Yes2 Yes3 No
Basemark Database save Yes Yes Possible4
Server access logs* Yes Yes Yes
Automated test run No Yes Yes
Source Code Access No No Yes
Battery Test Yes Yes Yes

*Server access logs are visible only for selected Basemark personnel and will be used only to monitor server activity in general level
1Local installation cannot test Page Load & Responsiveness capability
2Result will be submitted automatically to Power Board
3Result will be submitted automatically to Power Board after successful Full Test run
4Corporate mode users can select how data is treated: By default Basemark Web 3.0 doesn’t save anything, but user can also select that data is saved only for the corporate, or as public data